Key Features:
• Proprietary Ultra/WIO Form Factor
• Dual Socket P (LGA 3647)
• Intel® C621
• Up to 6TB of Memory
• Up to 28 cores
|
Product SKUs
| |
|---|---|
| MBD-X11DPU-Z+ | • X11DPU-Z+ |
| Physical Stats
|
|
|---|---|
| Form Factor | • Proprietary Ultra/WIO |
| Dimensions | • 17" x 16.8" (43.18cm x 42.67cm) |
|
Processor/Cache
| |
|---|---|
| CPU | • 2nd Generation Intel® Xeon® Scalable Processors (Cascade Lake-SP), Intel® Xeon® Scalable Processors |
| Cores/Cache | • Up to 28 cores |
|
System Memory
| Memory Capacity | • Up to 6TB 3DS ECC RDIMM, DDR4-2933MHz; Up to 6TB 3DS ECC LRDIMM, DDR4-2933MHz, in 24 DIMM slots • Up to 6TB Intel® Optane„¢ DC Persistent Memory in memory mode (Cascade Lake only) |
|---|---|
| Memory Type | • 2933/2666/2400/2133MHz ECC DDR4 RDIMM, LRDIMM |
| DIMM Sizes | • RDIMM: 64GB, 128GB • LRDIMM: 64GB, 128GB • 3DS LRDIMM: 128GB, 256GB |
| Memory Voltage | • 1.2V |
| Error Detection | •
Corrects single-bit errors • Detects double-bit errors (using ECC memory) |
|
OnBoard Devices
| Chipset | • Intel® C621 |
|---|---|
| SATA | • Intel® C621 controller for 10 SATA3 (6 Gbps) ports; SATA3 (6 Gbps) RAID 0,1,5,10 |
| IPMI | • ASPEED AST2500 |
| Network Controllers | • Networking options provided via Ultra Riser |
| Graphics | • Aspeed AST2500 BMC |
|
Input/Output
| |
|---|---|
| USB | • 3 USB 3.0 ports (2 rear + 1 header) |
| Video Output | • 1 VGA port |
| Serial Port/Header |
• 1 COM Port (1 rear) |
| TPM |
• 1 TPM Header |
| Others |
• 2 ports SuperDOM |
|
Expansion Slots
| |
|---|---|
| PCI-E | • 1 PCI-E 3.0 x32 Left Riser Slot |
|
System BIOS
| |
|---|---|
| BIOS Type | • AMI UEFI |
|
Management
| |
|---|---|
| Software | • Intel® Node Manager, IPMI2.0, KVM with dedicated LAN, NMI, SPM, SUM, SuperDoctor® 5, Watchdog |
| Power Configuration | • ACPI Power Management |
|
PC Health Monitoring
| |
|---|---|
| Voltage | • +12V, +3.3V, +5V, +5V standby, 3.3V standby |
| FAN | • 8x 4-pin fan headers (up to 8 fans), 8x fans with tachometer monitoring, PWM fan speed control, Status monitoring for speed control |
| Temperature | • CPU thermal trip support, Monitoring for CPU and chassis environment |
| LED | • CPU / System Overheat LED, UID/Remote UID, BMC/IPMI Heartbeat LED, Power LED |
| Other Features | • Chassis intrusion detection, Chassis intrusion header, RoHS, SDDC |
|
Operating Environment
| |
|---|---|
| Operating Temperature Range |
• 10°C - 35°C (50°F - 95°F) |
| Non-Operating Temperature Range |
• -40°C - 70°C (-40°F - 158°F) |
| Operating Relative Humidity Range |
• 8% - 90% (non-condensing) |
| Non-Operating Relative Humidity Range |
• 5% - 95% (non-condensing) |