Supermicro Server Board X11DPT-B | LGA 3647 | Proprietary Twin
Key Features:
• Proprietary Twin Form Factor
• Dual Socket P (LGA 3647)
• Intel® C621
• Up to 6TB of Memory
• Up to 28 cores
Product SKUs
| |
---|---|
MBD-X11DPT-B | • X11DPT-B |
Physical Stats
|
|
---|---|
Form Factor | • Proprietary Twin |
Dimensions | • 7.62" x 18.86" (19.35cm x 47.9cm) |
Processor/Cache
| |
---|---|
CPU | • 2nd Generation Intel® Xeon® Scalable Processors (Cascade Lake-SP), Intel® Xeon® Scalable Processors |
Cores/Cache | • Up to 28 cores |
Note | • BIOS version 3.0a or above is required to support 2nd Generation Intel Xeon Scalable Processors-SP |
System Memory
| Memory Capacity | • Up to 6TB 3DS ECC RDIMM, DDR4-2933MHz; Up to 6TB 3DS ECC LRDIMM, DDR4-2933MHz, in 24 DIMM slots • Up to 6TB Intel® Optane„¢ DC Persistent Memory in memory mode (Cascade Lake only) |
---|---|
Memory Type | • 2933/2666/2400/2133MHz ECC DDR4 RDIMM, LRDIMM |
DIMM Sizes | • RDIMM: 64GB • LRDIMM: 64GB • 3DS LRDIMM: 128GB, 256GB |
Memory Voltage | • 1.2V |
Error Detection | • Corrects single-bit errors • Detects double-bit errors (using ECC memory) |
OnBoard Devices
| Chipset | • Intel® C621 |
---|---|
SATA | • Intel® C621 controller for SATA3 (6 Gbps) ports; RAID 0,1,5,10 |
IPMI | • ASPEED AST2500 |
Network Controllers | • Single LAN with Networking options provided via SIOM module |
Graphics | • Aspeed AST2500 BMC |
Input/Output
| |
---|---|
SATA | • 8 SATA3 (6Gbps) port |
USB | • 2 USB 3.0 ports (2 rear) |
Video Output |
• 1 VGA port |
TPM | • 1 TPM Header |
Expansion Slots
| |
---|---|
PCI-E | • 1 PCI-E 3.0 x16 Left Riser Slot |
System BIOS
| |
---|---|
BIOS Type | • AMI UEFI |
Management
| |
---|---|
Software | • Intel® Node Manager, IPMI2.0, KVM with dedicated LAN, SPM, SSM, SUM, SuperDoctor® 5, Watchdog |
Power Configuration | • ACPI Power Management |
PC Health Monitoring
| |
---|---|
Voltage | • +1.8V, +12V, +3.3V, +5V, +5V standby, 1.05 (PCH), Chipset Voltage, Memory Voltages, Monitors CPU voltages |
FAN | • 2x 4-pin fan headers (up to 2 fans), PWM fan speed control |
Temperature | • CPU thermal trip support, Monitoring for CPU and chassis environment |
LED | • BMC/IPMI Heartbeat LED, UID/Remote UID |
Other Features | • Chassis intrusion detection, CPU thermal trip support for processor protection, Node Manager Support, RoHS, SDDC, UID, WOL |
Operating Environment
| |
---|---|
Operating Temperature Range |
• 10°C - 35°C (50°F - 95°F) |
Non-Operating Temperature Range |
• -40°C - 70°C (-40°F - 158°F) |
Operating Relative Humidity Range |
• 8% - 90% (non-condensing) |
Non-Operating Relative Humidity Range |
• 5% - 95% (non-condensing) |